Emulated Signal Generator 4-20mA 420LGPM

Emulated Signal Generator 4-20mA 420LGPM

  • AS420LGPM
600,000 VND

2-wire 4-20mA Loop Simulator Parameters

Output current signal:default 4–20mA, max. 3mA—21mA
Power supply voltage:15V—30V
Sampling resistor:10Ω—500Ω
Display precision:0.01mA max.
Output precision:±0.5%
Physical size (front):79.5x42mm
Physical size (back):72.5×39.5mm
Install panel /Panel cut-out size:77x40mm (±1mm error)

Datasheet Link Download

420LGPM 2-wire 4-20mA loop simulator set-point signal generator with panel mounted shell supports digital programming setting, cures output, 4-20mA current loop signal output and display, parameters save. Its output range and diplay mode can be set through the knob. It works with Siemens PLC and other PLCs, and also can be used in 3-wire 4-20mA simulation, 4-wire 4-20mA simulation by adding resistance. Low power consumption, stable output, it is a essential simplified calibration and testing meter instead of fluke 4-20mA loop calibrator in industrial sites and labs.

2-wire 4-20mA Loop Simulator Features and Benefits
• LCD display (with back light); display mode: 4-20mA current value or 0-100 (%) percentage or 0.0-50.0 (Hz), display mode is settable via knob.
• 9 Segments programmable output (stimulative real environment dynamic testing, each segment can be set: “t” run time/”A” starting current/”b” ending current).
• Using accurate digital rotary encoder, not potentiometer (the current generator with potentiometer is easily affected by temperature and humidity, and the resistance maybe change in operation).
• Output range can be 4-20mA default or max. 3-21mA, output range is settable and programmable.
• Have reverse polarity protection (two-wire connection, no need to check positvie or negative terminal, it can work properly, will not burn meter).
• High precision and linearity (display precision “0.05”, two decimal points, actual output accuracy ±0.5%).
• Low power consumption, low heat , more stable output.
• Refined elegant shell, standard panel-mounted design, easy to do further integration.

2-wire 4-20mA Simulation Output Wiring
(That 4-20mA signal generator connection does not have positive and negative polarity, no power supply required in 4-20mA loop application. 3-wire 4-wire application diagram is similar to that of 2-wire loop wiring circuit. *Please download user manul at the bottom of this page.)

Wiring Circuit for 4-20mA Loop Simulator
Wiring Circuit for 4-20mA Loop Simulator
2-wire 4-20mA Loop Simulator
2-wire 4-20mA Loop Simulator (can be applied for Siemens PLC)

3-wire 4-20mA Calibration Wiring Circuit

3-wire 4-20mA Signal Calibration Circuit
3-wire 4-20mA Signal Calibration Circuit

4-wire 4-20mA Calibration Wiring Circuit

4-20mA Simulator 4-wire Application Circuit
4-20mA Simulator 4-wire Application
4-20mA Simulator 4-wire Application
4-20mA Simulator 4-wire Application

4-20mA Current Signal Measurement

Brightwin 4-20mA Loop Simulator Testing Meter
4-20mA Loop Simulator Measurement

Curve Output

4-20 milliamp Signal Generator Curve Output
4-20 milliamp Generator Curve Output

Model : AS-420LGPM
Importer and distributor: An Sinh
Quality: 100% New
Warranty genuine