Flow Sensors / Flow Meters

HOT

SV7200

9,701,946 VND

Application
Applicationfor industrial applications
Mediawater
Medium temperature [°C]-10...90
Pressure rating [bar]12
Note on pressure rating
up to 40 °C
MAWP (for applications according to CRN) [bar]4.3
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 30
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]< 3
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range
5...100 l/min0.3...6 m³/h
Display range
0...120 l/min0...7.2 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
6...100 l/min0.36...6 m³/h
Reset point rP
5...99 l/min0.3...5.94 m³/h
Frequency end point, FEP
20...100 l/min1.2...6 m³/h
In steps of
0.5 l/min0.02 m³/h
Frequency at the end point FRP [Hz]100...1000
Measuring dynamics1:20
Temperature monitoring
Measuring range [°C]-10...90
Display range [°C]-30...110
Resolution [°C]0.5
Set point SP [°C]-9...90
Reset point rP [°C]-10...89
In steps of [°C]0.5
Frequency start point, FSP [°C]-10...70
Frequency end point, FEP [°C]10...90
Frequency at the end point FRP [Hz]100...1000
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit
Operating conditions
Ambient temperature [°C]0...60
Note on ambient temperature
medium temperature < 80 °C
medium temperature < 90 °C: 0...50 °C
Storage temperature [°C]-20...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]483.5
Materialsstainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
Tightening torque [Nm]30
Process connectionthreaded connection G 3/4 DN20
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SU7000

20,441,375 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediawater; glycol solutions; coolants; oil
Note on media
low-viscosity oils with viscosity: 7...40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30...68 mm²/s (40 °C)
Medium temperature [°C]-10...80
Pressure rating [bar]16
Electrical data
Operating voltage [V]19...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]100
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0...50 l/min0...3 m³/h
Display range
0...60 l/min0...3.6 m³/h
Resolution
0.1 l/min0.005 m³/h
Set point SP
0.1...50 l/min0.005...3 m³/h
Reset point rP
0...49.9 l/min0...2.995 m³/h
Analogue start point ASP
0...40 l/min0...2.4 m³/h
Analogue end point AEP
10...50 l/min0.6...3 m³/h
Max. flow rate
60 l/min3.6 m³/h
In steps of
0.1 l/min0.005 m³/h
Volumetric flow quantity monitoring
Pulse value0.1 l...1 000 000 m³
Pulse length [s]0,05...2
Temperature monitoring
Measuring range [°C]-10...80
Resolution [°C]0.2
Set point SP [°C]-9.8...80
Reset point rP [°C]-10...79.8
Analogue start point [°C]-10...62
Analogue end point [°C]8...80
In steps of [°C]0.2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]1551.5
Materialshousing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA
Materials (wetted parts)stainless steel (1.4404 / 316L); FKM; PES; Centellen 200
Process connectionthreaded connection G 3/4 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated
Buy
HOT

SA4100

9,224,704 VND

Application
Mediawater; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C]-20...100
Pressure rating [bar]50
MAWP (for applications according to CRN) [bar]50
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]250
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]350
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0...1000
Measuring/setting range
Probe length L [mm]100
Operating moderelative; absolutely liquid; absolutely gaseous
Note on setting range
Operating mode: relative
Liquids
Measuring range [m/s]0.04...3
Setting range [m/s]0...6
Gases
Measuring range [m/s]2...100
Setting range [m/s]0...200
Temperature monitoring
Measuring range [°C]-20...100
Resolution [°C]0.2
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Operating conditions
Ambient temperature [°C]-40...80
Storage temperature [°C]-40...100
ProtectionIP 65; IP 67
Mechanical data
Weight [g]299.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30
Materials (wetted parts)stainless steel (1.4404 / 316L)
Process connectiondiameter Ø 8 mm
Displays / operating elements
Display
Display unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SA5000

8,898,638 VND

Application
Mediawater; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C]-20...90
Pressure rating [bar]100
MAWP (for applications according to CRN) [bar]100
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]250
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]350
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0...1000
Measuring/setting range
Probe length L [mm]45
Operating moderelative; absolutely liquid; absolutely gaseous
Note on setting range
Operating mode: relative
Liquids
Measuring range [m/s]0.04...3
Setting range [m/s]0...6
Gases
Measuring range [m/s]2...100
Setting range [m/s]0...200
Temperature monitoring
Measuring range [°C]-20...90
Resolution [°C]0.2
Software / programming
Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Operating conditions
Ambient temperature [°C]-40...80
Storage temperature [°C]-40...100
ProtectionIP 65; IP 67
Mechanical data
Weight [g]311.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts)stainless steel (1.4404 / 316L); Gasket: FKM
Process connectionthreaded connection M18 x 1,5 internal thread
Displays / operating elements
Display
Display unit6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SI5004

8,498,466 VND

Application
MediaLiquids
Medium temperature [°C]-25...80
Pressure rating [bar]300
MAWP (for applications according to CRN) [bar]208
Electrical data
Operating voltage [V]19...36 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]500
Overload protectionyes
Measuring/setting range
Liquids
Setting range [cm/s]3...300
Greatest sensitivity [cm/s]3...100
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-25...100
ProtectionIP 67
Mechanical data
Weight [g]248
Dimensions [mm]M18 x 1.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X
Materials (wetted parts)stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connectionM18 x 1,5 internal thread
Displays / operating elements
Display
function10 x LED, three-colour
Electrical connection
ConnectionConnector: 1 x M12
Buy

SM0510

29,491,189 VND

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...900 l/min0.3...54 m³/h
Display range
-920...920 l/min-55.2...55.2 m³/h
Resolution
1 l/min0.05 m³/h
Set point SP
10...900 l/min0.55...54 m³/h
Reset point rP
5...896 l/min0.3...53.75 m³/h
Analogue start point ASP
0...720 l/min0...43.2 m³/h
Analogue end point AEP
180...900 l/min10.8...54 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
1 l/min0.05 m³/h
Measuring dynamics1:180
Volumetric flow quantity monitoring
Pulse value0.1 l...600 x 10³ m³
In steps of0.1 l
Pulse length [s]0,003...2
Temperature monitoring
Measuring range [°C]-20...80
Display range [°C]-40...100
Resolution [°C]0.2
Set point SP [°C]-19.2...80
Reset point rP [°C]-19.6...79.6
Analogue start point [°C]-20...60
Analogue end point [°C]0...80
In steps of [°C]0.2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3212
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PC; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Hastelloy C-4 (2.4610); Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM4000

16,226,231 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]0...60
Pressure rating [bar]10
MAWP (for applications according to CRN) [bar]7.3
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range [ml/min]5...3000
Display range [ml/min]-1999...3600
Resolution [ml/min]1
Set point SP [ml/min]20...3000
Reset point rP [ml/min]5...2984
Analogue start point ASP [ml/min]0...2400
Analogue end point AEP [ml/min]600...3000
Low flow cut-off LFC [ml/min]< 60
Volumetric flow quantity monitoring
Pulse value0.001...3000 l
Pulse length [s]0,008...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]536.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/4 DN6 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (ml/min, l/h, l, m³, °C, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM6001

15,375,494 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
1.5...396 gph0.03...6.6 gpm
Display range
-475.5...475.5 gph-7.925...7.925 gpm
Resolution
0.5 gph0.01 gpm
Set point SP
3.5...396.5 gph0.06...6.6 gpm
Reset point rP
1.5...394 gph0.03...6.57 gpm
Analogue start point ASP
0...318 gph0...5.3 gpm
Analogue end point AEP
78...396 gph1.3...6.6 gpm
In steps of
0.5 gph0.01 gpm
Volumetric flow quantity monitoring
Pulse value0.01...30 000 000 gal
Pulse length [s]0,01...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°F]14...140
Storage temperature [°F]-13...176
ProtectionIP 67
Mechanical data
Weight [g]546
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM8001

20,441,375 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
6...1584 gph0.1...26.4 gpm
Display range
-1902...1902 gph-31.7...31.7 gpm
Resolution
2 gph0.05 gpm
Set point SP
14...1586 gph0.25...26.4 gpm
Reset point rP
6...1578 gph0.1...26.25 gpm
Analogue start point ASP
0...1272 gph0...21.2 gpm
Analogue end point AEP
312...1586 gph5.2...26.4 gpm
In steps of
2 gph0.05 gpm
Volumetric flow quantity monitoring
Pulse value0.01...100 000 000 gal
Pulse length [s]0,0025...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°F]14...140
Storage temperature [°F]-13...176
ProtectionIP 67
Mechanical data
Weight [g]645
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM9100

24,932,193 VND

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...300 l/min0.3...18 m³/h
Display range
-360...360 l/min-21.6...21.6 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
6.5...300 l/min0.4...18 m³/h
Reset point rP
5...298.5 l/min0.3...17.9 m³/h
Analogue start point ASP
0...240 l/min0...14.4 m³/h
Analogue end point AEP
60...300 l/min3.6...18 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
0.5 l/min0.02 m³/h
Measuring dynamics1:60
Volumetric flow quantity monitoring
Pulse value0.0001...300x10³ m³
In steps of0.0001 m³
Pulse length [s]0,016...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3214
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM2004

28,936,876 VND

Application
Applicationempty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature
-10...70 °C14...158 °F
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 2
Outputs
Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output [mA]4...20; (≤ 22 mA; scalable)
Max. load [Ω]500
Measuring/setting range
Measuring range
5...600 l/min0.3...36 m³/h80...9510 gph1.3...158.5 gpm
Display range
-720...720 l/min-43.2...43.2 m³/h-11410...11410 gph-190.2...190.2 gpm
Resolution
0.5 l/min0.02 m³/h5 gph0.1 gpm
Analogue start point ASP
0...480 l/min0...28.8 m³/h0...7610 gph0...126.8 gpm
Analogue end point AEP
120...600 l/min7.2...36 m³/h1900...9510 gph31.7...158.5 gpm
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h< 240 gph< 4 gpm
In steps of
0.5 l/min0.02 m³/h5 gph0.1 gpm
Measuring dynamics1:120
Software / programming
Parameter setting optionsdisplay can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature
-10...60 °C14...140 °F
Storage temperature
-25...80 °C-13...176 °F
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9 
Shock resistance
DIN EN 60068-2-2720 g (11 ms)
Vibration resistance
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF [years]78
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g]3147
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
function display1 x LED, yellow (10³)
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM7004

18,117,413 VND

Application
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]20...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]120; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 2
Outputs
Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Overload protectionyes
Measuring/setting range
Measuring range
0.2...50 l/min0.02...13.22 gpm
Display range
-60...60 l/min-15.86...15.86 gpm
Resolution
0.1 l/min0.02 gpm
Analogue start point ASP
0...40 l/min0...10.58 gpm
Analogue end point AEP
10...50 l/min2.64...13.22 gpm
In steps of
0.1 l/min0.02 gpm
Temperature monitoring
Measuring range [°C]-20...80
Resolution [°C]0.2
Analogue start point [°C]-20...60
Analogue end point [°C]0...80
In steps of [°C]0.2
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]559.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 3/4 DN20 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy