Application |
---|
Media | Liquids; viscous media; powder |
Recommended media | water; hydrous media; oils; oil-based media; powder |
Cannot be used for | See the operating instructions, chapter "Function and features". |
Probe length [mm] | 40 |
Tank pressure [bar] | -1...40 |
MAWP (for applications according to CRN) [bar] | 40 |
Oil |
---|
Medium temperature [°C] | -20...100 |
Medium temperature short time [°C] | -20...150; (1 h) |
Water |
---|
Medium temperature [°C] | -20...100 |
Medium temperature short time [°C] | -20...150; (1 h) |
Electrical data |
---|
Operating voltage [V] | 18...30 DC |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; IO-Link |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 100 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Operating conditions |
---|
Ambient temperature [°C] | -20...85 |
Note on ambient temperature | Medium temperature: < 100 °C | -20...60 °C | Medium temperature: < 150 °C |
|
Storage temperature [°C] | -40...85 |
Protection | IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 252 |
Materials | stainless steel (1.4404 / 316L); PEEK; PEI; FKM |
Materials (wetted parts) | PEEK; FKM |
Process connection | 1/2" NPT |
Surface characteristics Ra/Rz of the wetted parts | < 0.8 |
Displays / operating elements |
---|
Display | switching status | 2 LED, yellow | operating status | 2 LED, green |
|
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |