HOT

IF7107

634,057 VND

Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designNPN
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]800
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]4
Real sensing range Sr [mm]4 ± 10 %
Operating distance [mm]0...3.25
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]93.2
Mountingnon-flush mountable
Dimensions [mm]M12 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²
Buy
HOT

IF7104

634,057 VND

Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designPNP
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]800
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]2
Real sensing range Sr [mm]2 ± 10 %
Operating distance [mm]0...1.62
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]94.7
Mountingflush mountable
Dimensions [mm]M12 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²
Buy

IF7106

634,057 VND

Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designNPN
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]800
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]2
Real sensing range Sr [mm]2 ± 10 %
Operating distance [mm]0...1.62
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]95
Mountingflush mountable
Dimensions [mm]M12 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²
Buy
HOT

IF7100

596,915 VND

Electrical data
Operating voltage [V]10...30 DC
Current consumption [mA]< 10
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designPNP
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]800
Short-circuit protectionyes
Overload protectionyes
Detection zone
Sensing range [mm]2
Real sensing range Sr [mm]2 ± 10 %
Operating distance [mm]0...1.62
Accuracy / deviations
Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
Hysteresis [% of Sr]3...15
Switch point drift [% of Sr]-10...10
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]28
Mountingflush mountable
Dimensions [mm]M12 x 1 / L = 60
Materialsbrass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection - plug
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

IF7102

596,915 VND

Electrical data
Operating voltage [V]10...30 DC
Current consumption [mA]< 10
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designNPN
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]700
Short-circuit protectionyes
Overload protectionyes
Detection zone
Sensing range [mm]2
Real sensing range Sr [mm]2 ± 10 %
Operating distance [mm]0...1.62
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]28
Mountingflush mountable
Dimensions [mm]M12 x 1 / L = 60
Materialsbrass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection - plug
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

IF7101

596,915 VND

Product characteristics
Electrical designPNP
Output functionnormally open
Sensing range [mm]4
Housingthreaded type
Dimensions [mm]M12 x 1 / L = 60
Electrical data
Operating voltage [V]10...30 DC
Current consumption [mA]< 10
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designPNP
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]700
Short-circuit protectionyes
Overload protectionyes
Detection zone
Sensing range [mm]4
Real sensing range Sr [mm]4 ± 10 %
Operating distance [mm]0...3.24
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]27.2
Housingthreaded type
Mountingnon-flush mountable
Dimensions [mm]M12 x 1 / L = 60
Thread designationM12 x 1
Materialsbrass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection - plug
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

IF7105

634,057 VND

Product characteristics
Electrical designPNP
Output functionnormally open
Sensing range [mm]4
Housingthreaded type
Dimensions [mm]M12 x 1 / L = 61
Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designPNP
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]800
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]4
Real sensing range Sr [mm]4 ± 10 %
Operating distance [mm]0...3.25
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]93.8
Mountingnon-flush mountable
Dimensions [mm]M12 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²
Buy

SM9004

25,323,472 VND

Application
Applicationempty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature
-10...70 °C14...158 °F
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 2
Outputs
Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output [mA]4...20; (≤ 22 mA; scalable)
Max. load [Ω]500
Measuring/setting range
Measuring range
5...300 l/min0.3...18 m³/h80...4755 gph1.3...79.3 gpm
Display range
-360...360 l/min-21.6...21.6 m³/h-5705...5705 gph-95.1...95.1 gpm
Resolution
0.5 l/min0.02 m³/h5 gph0.1 gpm
Analogue start point ASP
0...240 l/min0...14.4 m³/h0...3800 gph0...63.4 gpm
Analogue end point AEP
60...300 l/min3.6...18 m³/h955...4755 gph15.9...79.3 gpm
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h< 240 gph< 4 gpm
In steps of
0.5 l/min0.02 m³/h5 gph0.1 gpm
Measuring dynamics1:60
Software / programming
Parameter setting optionsdisplay can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature
-10...60 °C14...140 °F
Storage temperature
-25...80 °C-13...176 °F
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3140.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
function display1 x LED, yellow (10³)
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM8100

20,441,375 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.2...100 l/min0.01...6 m³/h
Display range
-120...120 l/min-7.2...7.2 m³/h
Resolution
0.1 l/min0.005 m³/h
Set point SP
0.7...100 l/min0.04...6 m³/h
Reset point rP
0.2...99.5 l/min0.01...5.97 m³/h
Analogue start point ASP
0...80 l/min0...4.8 m³/h
Analogue end point AEP
20...100 l/min1.2...6 m³/h
In steps of
0.1 l/min0.005 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...100 000 m³
Pulse length [s]0,0025...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]639.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; EPDM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM8004

20,841,546 VND

Application
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]20...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]120; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 2
Outputs
Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Overload protectionyes
Measuring/setting range
Measuring range
0.2...100 l/min0.1...26.4 gpm
Display range
-120...120 l/min-31.7...31.7 gpm
Resolution
0.1 l/min0.05 gpm
Analogue start point ASP
0...80 l/min0...21.1 gpm
Analogue end point AEP
20...100 l/min5.3...26.4 gpm
In steps of
0.1 l/min0.05 gpm
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]618.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM2000

28,545,597 VND

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...600 l/min0.3...36 m³/h
Display range
-720...720 l/min-43.2...43.2 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
8...600 l/min0.5...36 m³/h
Reset point rP
5...597 l/min0.3...35.8 m³/h
Analogue start point ASP
0...480 l/min0...28.8 m³/h
Analogue end point AEP
120...600 l/min7.2...36 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
0.5 l/min0.02 m³/h
Measuring dynamics1:120
Volumetric flow quantity monitoring
Pulse value0.0001...600x10³ m³
In steps of0.0001 m³
Pulse length [s]0,008...2
Temperature monitoring
Measuring range [°C]-20...80
Display range [°C]-40...100
Resolution [°C]0.2
Set point SP [°C]-19.2...80
Reset point rP [°C]-19.6...79.6
Analogue start point [°C]-20...60
Analogue end point [°C]0...80
In steps of [°C]0.2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3178
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Accessories
Accessories (supplied)
sealings: 2, Centellen
Label
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM6100

15,375,494 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.1...25 l/min0.005...1.5 m³/h
Display range
-30...30 l/min-1.8...1.8 m³/h
Resolution
0.02 l/min0.002 m³/h
Set point SP
0.25...25 l/min0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min0...1.2 m³/h
Analogue end point AEP
5...25 l/min0.3...1.5 m³/h
In steps of
0.02 l/min0.002 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...30 000 m³
Pulse length [s]0,01...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]548
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; EPDM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy