Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Output signal | Switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | Normally open / normally closed; (parameterisable) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20, invertible; (scalable) |
Short-circuit protection | Yes |
Type of short-circuit protection | Pulsed |
Overload protection | Yes |
Measuring range | -0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O |
Application | Hygienic systems |
Media | Viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] | -25...125; (145 max. 1h) |
Pressure rating | 6000 mbar 2400 inH2O |
Min. bursting pressure | 30000 mbar 12044 inH2O |
Vacuum resistance [mbar] | -1000 |
Type of pressure | Relative pressure |
No dead space | Yes |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | Yes |
Integrated watchdog | Yes |
2-wire | Operating voltage [V] | 20...32 DC |
Current consumption [mA] | 3.6...21 |
Power-on delay time [s] | 1 |
Max. load [Ω] | 300 |
Step response time analogue output [ms] | 45 |
3-wire | Operating voltage [V] | 18...32 DC |
Current consumption [mA] | < 45 |
Power-on delay time [s] | 0.5 |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 125 |
Max. load [Ω] | (Ub - 10 V) / 20 mA |
Min. response time of switching output (dAP) [ms] | 3 |
Measuring range | -0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O |
Set point SP | -12...250 mbar -4.8...100.4 inH2O |
Reset point rP | -12.4...249.6 mbar -5...100.2 inH2O |
Analogue start point | -12.4...187.4 mbar -5...75.2 inH2O |
Analogue end point | 50...250 mbar 20.1...100.4 inH2O |
In steps of | 0.2 mbar 0.1 inH2O |
Response times | Damping for the switching output dAP [s] 0...30 Damping for the analogue output dAA [s] 0.01...99.99 |
Step response time analogue output [ms] | 7 |
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 67; IP 68; IP 69K |
Weight [g] | 356.5 |
Materials | Stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts) | Ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4 |
Min. pressure cycles | 100 million |
Display | Display unit | LED, green |
Switching status | LED, yellow |
Function display | Alphanumeric display, 4-digit |
Measured values | Alphanumeric display, 4-digit |
Display unit | mbar; kPa; inH2O; mmWS; % of the span |
Process connection | Threaded connection G 1 external thread Aseptoflex Vario |
Connection | Connector: 1 x M12; Contacts: gold-plated |