IoT Solutions

HOT

SI5006

9,461,843 VND

Application
MediaLiquids; Gases
Medium temperature [°C]-25...80
Pressure rating [bar]300
MAWP (for applications according to CRN) [bar]208
Liquids
Medium temperature [°C]-25...80
Gases
Medium temperature [°C]-25...80
Electrical data
Operating voltage tolerance [%]-5...10
Operating voltage [V]85...265 AC
Nominal voltage AC [V]90...240
Nominal frequency AC [Hz]50...60
Max. power consumption [VA]3.5
Protection classII
Reverse polarity protectionno
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 1
Outputs
Total number of outputs1
Output signalswitching signal
Electrical designrelay
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Contact rating3 A (250 V AC / 30 V DC); (number of switching cycles: 20 million mechanically; switching cycles at 3 A load: 100,000 electrical; type of switch-off: normally open)
Short-circuit proofno
Overload protectionno
Measuring/setting range
Liquids
Setting range [cm/s]3...300
Greatest sensitivity [cm/s]3...100
Gases
Setting range [cm/s]200...3000
Greatest sensitivity [cm/s]200...800
Software / programming
Adjustment of the switch pointpushbutton
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-25...100
ProtectionIP 67
Mechanical data
Weight [g]262.5
Dimensions [mm]M18 x 1.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X
Materials (wetted parts)stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connectionM18 x 1,5 internal thread
Displays / operating elements
Display
function10 x LED, three-colour
Electrical connection
ConnectionConnector: 1 x 1/2"
Buy
HOT

SI5010

9,034,993 VND

Application
MediaLiquids; Gases
Medium temperature [°C]-25...80
Pressure rating [bar]300
MAWP (for applications according to CRN) [bar]208
Liquids
Medium temperature [°C]-25...80
Gases
Medium temperature [°C]-25...80
Electrical data
Operating voltage [V]18...36 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 1
Outputs
Total number of outputs1
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]250
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Liquids
Setting range [cm/s]3...300
Greatest sensitivity [cm/s]3...100
Gases
Setting range [cm/s]200...3000
Greatest sensitivity [cm/s]200...800
Software / programming
Adjustment of the switch pointpushbutton
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-25...100
ProtectionIP 65; IP 67
Mechanical data
Weight [g]248.5
Dimensions [mm]M18 x 1.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X
Materials (wetted parts)stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connectionM18 x 1,5 internal thread
Displays / operating elements
Display
function10 x LED, three-colour
Electrical connection
ConnectionConnector: 1 x M12
Buy

SR5906

7,040,061 VND

Application
ApplicationFlow monitoring; Wire monitoring
Electrical data
Operating voltage tolerance [%]-15...10
Operating voltage [V]76.5...264 AC
Nominal voltage AC [V]90...240
Nominal frequency AC [Hz]50...60
Max. power consumption [VA]3.5
Protection classII
Reverse polarity protectionno
Power-on delay time [s]10
Number of channels1
Outputs
Electrical designrelay
Contact rating3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open)
Switching cycles (mechanical)20_Millionen
Switching function flow monitoringoutput switches when flow is present: ON for output function = normally open / OFF for output function = normally closed
Short-circuit protectionno
Overload protectionno
Software / programming
Adjustment of the switch pointpushbutton
Operating conditions
Ambient temperature [°C]-20...60
ProtectionIP 67; (with sensor attached)
Mechanical data
Weight [g]244.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Displays / operating elements
Display
functionLED, bar graph
switching statusLED, orange flash in case of wire break
Electrical connection
ConnectionConnector: 1 x 1/2"
Buy

SR5900

6,435,358 VND

Application
ApplicationFlow monitoring; Wire monitoring
Electrical data
Operating voltage [V]19...36 DC
Current consumption [mA]< 70
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Number of channels1
Outputs
Electrical designPNP
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]250
Switching function flow monitoringoutput switches when flow is present: ON for output function = normally open / OFF for output function = normally closed
Short-circuit protectionyes
Overload protectionyes
Software / programming
Adjustment of the switch pointpushbutton
Operating conditions
Ambient temperature [°C]-20...60
ProtectionIP 67; (with sensor attached)
Mechanical data
Weight [g]225.5
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Displays / operating elements
Display
functionLED, bar graph
switching statusLED, orange flash in case of wire break
Electrical connection
ConnectionConnector: 1 x M12
Buy

LDL100

15,854,067 VND

Application
Mediaconductive liquids
Note on media
water
milk
CIP liquids
Medium temperature [°C]-25...100; (< 1 h: 150)
Tank pressure [bar]-1...16
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link
Output functionanalogue output; scalable; selectable conductivity / temperature
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]500
Measuring/setting range
Conductivity measurement
Measuring range [µS/cm]100...15000
Temperature measurement
Measuring range [°C]-25...150
Temperature measurement
Response time [s]< 9; (T09)
Operating conditions
Ambient temperature [°C]-40...60
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Mechanical data
Weight [g]270.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK; stainless steel (1.4404 / 316L)
Process connectionG 1/2 external thread
Electrical connection
ConnectionConnector: 1 x M12 (EN 61067-2-101); Contacts: gold-plated
Buy

LDL200

31,708,133 VND

Application
Mediaconductive liquids
Note on media
water
milk
CIP liquids
Medium temperature [°C]-25...100; (< 1 h: 150)
Tank pressure [bar]-1...16
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 70
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link
Output functionanalogue output; scalable; selectable conductivity / temperature
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]500
Measuring/setting range
Conductivity measurement
Measuring range [µS/cm]100...1000000
Temperature measurement
Measuring range [°C]-25...150
Conductivity measurement
Accuracy (in the measuring range)2 % MW ± 25 µS/cm
Resolution [µS/cm]1
Drift [%/K]0,1 %/K MW ± 25 µS/cm
Repeatability1 % MW ± 25 µS/cm
Long-term stability0,5 % MW ± 25 µS/cm
Operating conditions
Ambient temperature [°C]-40...60
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Mechanical data
Weight [g]580.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1 external thread Aseptoflex Vario
Electrical connection
ConnectionConnector: 1 x M12 (EN 61067-2-101); Contacts: gold-plated
Buy

SM0510

29,491,189 VND

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...900 l/min0.3...54 m³/h
Display range
-920...920 l/min-55.2...55.2 m³/h
Resolution
1 l/min0.05 m³/h
Set point SP
10...900 l/min0.55...54 m³/h
Reset point rP
5...896 l/min0.3...53.75 m³/h
Analogue start point ASP
0...720 l/min0...43.2 m³/h
Analogue end point AEP
180...900 l/min10.8...54 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
1 l/min0.05 m³/h
Measuring dynamics1:180
Volumetric flow quantity monitoring
Pulse value0.1 l...600 x 10³ m³
In steps of0.1 l
Pulse length [s]0,003...2
Temperature monitoring
Measuring range [°C]-20...80
Display range [°C]-40...100
Resolution [°C]0.2
Set point SP [°C]-19.2...80
Reset point rP [°C]-19.6...79.6
Analogue start point [°C]-20...60
Analogue end point [°C]0...80
In steps of [°C]0.2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3212
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PC; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Hastelloy C-4 (2.4610); Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM4000

16,226,231 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]0...60
Pressure rating [bar]10
MAWP (for applications according to CRN) [bar]7.3
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range [ml/min]5...3000
Display range [ml/min]-1999...3600
Resolution [ml/min]1
Set point SP [ml/min]20...3000
Reset point rP [ml/min]5...2984
Analogue start point ASP [ml/min]0...2400
Analogue end point AEP [ml/min]600...3000
Low flow cut-off LFC [ml/min]< 60
Volumetric flow quantity monitoring
Pulse value0.001...3000 l
Pulse length [s]0,008...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]536.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/4 DN6 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (ml/min, l/h, l, m³, °C, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy

SM6001

15,375,494 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
1.5...396 gph0.03...6.6 gpm
Display range
-475.5...475.5 gph-7.925...7.925 gpm
Resolution
0.5 gph0.01 gpm
Set point SP
3.5...396.5 gph0.06...6.6 gpm
Reset point rP
1.5...394 gph0.03...6.57 gpm
Analogue start point ASP
0...318 gph0...5.3 gpm
Analogue end point AEP
78...396 gph1.3...6.6 gpm
In steps of
0.5 gph0.01 gpm
Volumetric flow quantity monitoring
Pulse value0.01...30 000 000 gal
Pulse length [s]0,01...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°F]14...140
Storage temperature [°F]-13...176
ProtectionIP 67
Mechanical data
Weight [g]546
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM8001

20,441,375 VND

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating [bar]16
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
6...1584 gph0.1...26.4 gpm
Display range
-1902...1902 gph-31.7...31.7 gpm
Resolution
2 gph0.05 gpm
Set point SP
14...1586 gph0.25...26.4 gpm
Reset point rP
6...1578 gph0.1...26.25 gpm
Analogue start point ASP
0...1272 gph0...21.2 gpm
Analogue end point AEP
312...1586 gph5.2...26.4 gpm
In steps of
2 gph0.05 gpm
Volumetric flow quantity monitoring
Pulse value0.01...100 000 000 gal
Pulse length [s]0,0025...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°F]14...140
Storage temperature [°F]-13...176
ProtectionIP 67
Mechanical data
Weight [g]645
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

SM9100

24,932,193 VND

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...300 l/min0.3...18 m³/h
Display range
-360...360 l/min-21.6...21.6 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
6.5...300 l/min0.4...18 m³/h
Reset point rP
5...298.5 l/min0.3...17.9 m³/h
Analogue start point ASP
0...240 l/min0...14.4 m³/h
Analogue end point AEP
60...300 l/min3.6...18 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
0.5 l/min0.02 m³/h
Measuring dynamics1:60
Volumetric flow quantity monitoring
Pulse value0.0001...300x10³ m³
In steps of0.0001 m³
Pulse length [s]0,016...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3214
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated
Buy
HOT

Temperature Monitoring System, Cold Storage Humidity

Liên Hệ

 

Control unit for cold storage includes:

 
  • IoT Gateway :

Order code

WG3MD-001

Processor

Dual-Core Tensilica LX6 240MHz, RTC, 4 MB SRAM, 4MB SPI.

RS485

 

Wifi

RS485 : MODBUS MASTER (connect : max 8 Slave).

 

Modbus TCP/IP  On Wifi

Digital I/O

·         Incl. DI

·         Incl. DO

Analog input

8xDIO (with Ext up 32DI/32DO).

·         4x DI Protection : Over-Voltage 30VDC.

·         4x DO, Relay, Current 10A, 300W.

4x AI (4 ~ 20mA) ,Protection.

Wi-Fi

Ethernet

Lora

(optional)

3G/GPRS

WIFI     : 802.11b/g/n up 16mbps.

LAN       : Option.

Lora       : Option.

GPRS     : Option.

 

PROTOCOLS

MQTT /SIM/WiFi (Setting), OPC, Kepware,intouch.

Power supply

9~30 VDC.

Working temp

-40 ~ 85°C, humidity 5 ~ 95% RH (no condensation).

 

  • Rounter 4G HF8104 :

Integrated 4G SIM DATA to create the Internet. 

  • Temperature Sensors :

 

                                                          

Temperature Sensors TA2542

Manufacturer: IFM

Wide temperature range: -50 ° C to 200 ° C

Analogue current output [mA]: 4-20mA

Technology standards: IP67; IP68; IP69K.

Howling sirens: Sirens with flashing lights, alarm when something goes wrong.

LED board: Displays the temperature and humidity value.

Remote monitoring system:

Allows setting the allowed temperature threshold. When the temperature exceeds the set threshold, an alarm will be triggered
SMS alarm, set unlimited phone number for receiving messages.
Available SIM module, Wifi and LAN port to connect to the internet
Monitor and view the alert status of the system via webserver software, Smathphone
Export reports of warning events from time to time in excel file

Note

This is a remote temperature monitoring model, the company can customize it to suit the requirements of customers.

Buy