TA2012

5,168,861 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]100
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2,0
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]112.5
Dimensions [mm]Ø 18.73
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionClamp 3/4" ISO 2852
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]60
Electrical connection
ConnectionConnector: 1 x M12

 