TA2212

  • TA2212
  • IFM
4,754,575
Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]160
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]102.5
Dimensions [mm]Ø 18.7
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectiondiameter Ø 6 mm
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]50
Electrical connection
ConnectionConnector: 1 x M12

 

Hygienic design for the requirements of the food and beverage industry
Particularly good response dynamics and very short power-on delay time
High precision across the entire temperature measurement range
Precise analogue output and user-friendly communication via IO-Link
Robust stainless steel housing with high protection rating and high pressure rating

The compact temperature transmitters are specially designed for the food and beverage industry. They have an analogue output with 4...20 mA. 
The Pt1000 measuring element of class A achieves a high precision with the factory-internal calibration. The innovation besides the wide measuring range is the excellent response time. Thanks to their high protection rating, fully welded stainless steel housing and high pressure resistance, the transmitters are particularly suited for use in hygienic environments. An LED clearly signals the readiness for operation.
The sensors are available with different probe lengths, process connections and measuring ranges. A variety of adapters facilitates integration into the process.
The units can either be used as 2-wire or 4-wire units. When used as a 4-wire unit, the transmitter can be configured via IO-Link, e.g. using a USB interface. The LINERECORDER SENSOR software is used to visualise, transfer and archive parameter sets.

Model : TA2212
Hãng sản xuất: IFM
Chất lượng : Mới 100%
Bảo hành : Chính hãng
Chứng từ : CO/CQ, hóa đơn VAT

Bình luận

 Tags: Cảm biến ,