Thiết bị IFM

SM6100

15,375,494 ₫

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.1...25 l/min0.005...1.5 m³/h
Display range
-30...30 l/min-1.8...1.8 m³/h
Resolution
0.02 l/min0.002 m³/h
Set point SP
0.25...25 l/min0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min0...1.2 m³/h
Analogue end point AEP
5...25 l/min0.3...1.5 m³/h
In steps of
0.02 l/min0.002 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...30 000 m³
Pulse length [s]0,01...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]548
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; EPDM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

SM9000

24,932,193 ₫

Application
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]16.5
Electrical data
Operating voltage [V]18...32 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output [Hz]0.1...10000
Measuring/setting range
Measuring range
5...300 l/min0.3...18 m³/h
Display range
-360...360 l/min-21.6...21.6 m³/h
Resolution
0.5 l/min0.02 m³/h
Set point SP
6.5...300 l/min0.4...18 m³/h
Reset point rP
5...298.5 l/min0.3...17.9 m³/h
Analogue start point ASP
0...240 l/min0...14.4 m³/h
Analogue end point AEP
60...300 l/min3.6...18 m³/h
Low flow cut-off LFC
< 15 l/min< 0.9 m³/h
In steps of
0.5 l/min0.02 m³/h
Measuring dynamics1:60
Volumetric flow quantity monitoring
Pulse value0.0001...300x10³ m³
In steps of0.0001 m³
Pulse length [s]0,016...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
Mechanical data
Weight [g]3176
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM
Process connectionthreaded connection G 2 DN50 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

SM7000

17,717,241 ₫

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.2...50 l/min0.01...3 m³/h
Display range
-60...60 l/min-3.6...3.6 m³/h
Resolution
0.1 l/min0.001 m³/h
Set point SP
0.5...50 l/min0.027...3 m³/h
Reset point rP
0.2...49.8 l/min0.012...2.985 m³/h
Analogue start point ASP
0...40 l/min0...2.4 m³/h
Analogue end point AEP
10...50 l/min0.6...3 m³/h
In steps of
0.1 l/min0.001 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...50 000 m³
Pulse length [s]0,005...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]587
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 3/4 DN20 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

SM6004

15,677,846 ₫

Application
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]20...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]120; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 2
Outputs
Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Overload protectionyes
Measuring/setting range
Measuring range
0.1...25 l/min0.03...6.6 gpm
Display range
-30...30 l/min-7.92...7.92 gpm
Resolution
0.02 l/min0.01 gpm
Analogue start point ASP
0...20 l/min0...5.28 gpm
Analogue end point AEP
5...25 l/min1.32...6.6 gpm
In steps of
0.02 l/min0.01 gpm
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]516.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

SM8000

20,441,375 ₫

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]11.2
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.2...100 l/min0.01...6 m³/h
Display range
-120...120 l/min-7.2...7.2 m³/h
Resolution
0.1 l/min0.005 m³/h
Set point SP
0.7...100 l/min0.04...6 m³/h
Reset point rP
0.2...99.5 l/min0.01...5.97 m³/h
Analogue start point ASP
0...80 l/min0...4.8 m³/h
Analogue end point AEP
20...100 l/min1.2...6 m³/h
In steps of
0.1 l/min0.005 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...100 000 m³
Pulse length [s]0,0025...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]641.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

SM6000

15,375,494 ₫

Application
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating [bar]16
MAWP (for applications according to CRN) [bar]17.7
Electrical data
Operating voltage [V]18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]95; (24 V)
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]200
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Analogue voltage output [V]0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring range
0.1...25 l/min0.005...1.5 m³/h
Display range
-30...30 l/min-1.8...1.8 m³/h
Resolution
0.02 l/min0.002 m³/h
Set point SP
0.25...25 l/min0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min0...1.2 m³/h
Analogue end point AEP
5...25 l/min0.3...1.5 m³/h
In steps of
0.02 l/min0.002 m³/h
Volumetric flow quantity monitoring
Pulse value0.00001...30 000 m³
Pulse length [s]0,01...2
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Operating conditions
Ambient temperature [°C]-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
Mechanical data
Weight [g]542.5
Materialsstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionthreaded connection G 1/2 DN15 flat seal
Displays / operating elements
Display
Display unit6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

TA2802

5,110,602 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]100
Vacuum resistance [mbar]-1000
MAWP (for applications according to CRN) [bar]55
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]228.5
Dimensions [mm]Ø 18.71
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionClamp 1,5" ISO 2852
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]30
Electrical connection
ConnectionConnector: 1 x M12

 

Mua hàng

TA2012

5,168,861 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]100
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2,0
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]112.5
Dimensions [mm]Ø 18.73
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionClamp 3/4" ISO 2852
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]60
Electrical connection
ConnectionConnector: 1 x M12

 

Mua hàng

TA2542

5,677,008 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]160
Vacuum resistance [mbar]-1000
MAWP (for applications according to CRN) [bar]160
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]239
Dimensions [mm]Ø 18.7
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionthreaded connection G 1/2 sealing cone
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]150
Electrical connection
ConnectionConnector: 1 x M12
Mua hàng

TA2532

5,589,620 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]160
Vacuum resistance [mbar]-1000
MAWP (for applications according to CRN) [bar]160
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]231.5
Dimensions [mm]Ø 18.7
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionthreaded connection G 1/2 sealing cone
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]100
Electrical connection
ConnectionConnector: 1 x M12

 

Mua hàng

TA2212

4,754,575 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]160
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]102.5
Dimensions [mm]Ø 18.7
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectiondiameter Ø 6 mm
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]50
Electrical connection
ConnectionConnector: 1 x M12

 

Mua hàng

TA2002

5,110,602 ₫

Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]100
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2,0
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]109
Dimensions [mm]Ø 18.73
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionClamp 3/4" ISO 2852
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]25
Electrical connection
ConnectionConnector: 1 x M12

 

Mua hàng