LMT292

5,815,832 ₫

Application
Installationsuited for installation in existing tuning fork adapters
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Probe length [mm]28
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]295.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 3/4 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT392

5,931,437 ₫

Application
Installationsuited for installation in existing tuning fork adapters
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Probe length [mm]38
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]398.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

LMT202

5,815,832 ₫

Application
Installationsuited for installation in existing tuning fork adapters
MediaLiquids; viscous media; powder
Recommended mediawater; hydrous media; oils; oil-based media; powder
Probe length [mm]28
Tank pressure [bar]-1...40
Oil
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Water
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature: < 100 °C
-20...60 °C
Medium temperature: < 150 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]287.5
Dimensions [mm]Ø 30 / L = 112
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 3/4 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

LMT302

5,931,437 ₫

Application
Installationsuited for installation in existing tuning fork adapters
MediaLiquids; viscous media; powder
Recommended mediawater; hydrous media; oils; oil-based media; powder
Probe length [mm]38
Tank pressure [bar]-1...40
Oil
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Water
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature: < 100 °C
-20...60 °C
Medium temperature: < 150 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]391
Dimensions [mm]Ø 30 / L = 125.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT195

6,693,246 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Probe length [mm]253
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]401
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)PEEK; stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT194

6,571,712 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Probe length [mm]153
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]329
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)PEEK; stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT192

5,652,799 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Cannot be used forSee the operating instructions, chapter "Function and features".
Probe length [mm]38
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]249.5
Dimensions [mm]Ø 30 / L = 125
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT191

5,386,017 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Cannot be used forSee the operating instructions, chapter "Function and features".
Probe length [mm]11
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-40...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-40...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-40...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-40...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-40...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]217
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT04A

9,189,133 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]253
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]362
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT03A

8,857,139 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]153
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Factory settingoils; oil-based media; powder
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]329
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT01A

6,550,963 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]11
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Factory settingoils; oil-based media; powder
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]218
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT121

5,386,017 ₫

Number of inputs and outputs

Number of digital outputs: 2

Factory setting

Media with low water content

Process connection     

G 1/2 external thread

Application     

Media with low water content

Media                                                                         

Liquids; viscous media; powder

Probe length [mm]

11

Tank pressure [bar]

-1...40; (MAWP (for applications according to CRN): 40 bar / 4 MPa)

Oil, Water

Medium temperature [°C]

-40...100

Medium temperature short time [°C]   

-40...150; (1 h)

Operating voltage [V] 

18...30 DC

Current consumption [mA]

< 50

Protection class           

III

Reverse polarity protection

Yes

Output signal

Switching signal; IO-Link

Electrical design

PNP/NPN

Number of digital outputs                                                                   

2

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]   

100

Short-circuit protection           

Yes

Type of short-circuit protection                                  

Pulsed

Overload protection

Yes

Ambient temperature [°C]

-40...85

Storage temperature [°C]

-40...85

Protection

IP 68; IP 69K

Display

Switching status

LEDs, yellow

Operating status                                  

LEDs, green

Connection     

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng