Thiết bị đo

LMT194

6,571,712 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Probe length [mm]153
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]329
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)PEEK; stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT192

5,652,799 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Cannot be used forSee the operating instructions, chapter "Function and features".
Probe length [mm]38
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-25...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-25...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-25...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]249.5
Dimensions [mm]Ø 30 / L = 125
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT191

5,386,017 ₫

Application
MediaLiquids
Recommended mediawater; hydrous media; oils; oil-based media
Cannot be used forSee the operating instructions, chapter "Function and features".
Probe length [mm]11
Tank pressure [bar]-1...40; (applications subject to the German Federal Water Act : -0,5...10 bar)
Oil
Medium temperature [°C]-40...100; (applications subject to the German Federal Water Act 0...100 °C)
Medium temperature short time [°C]-40...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Water
Medium temperature [°C]-40...85; (applications subject to the German Federal Water Act : 0...85 °C)
Medium temperature short time [°C]-40...150; (1 h; applications subject to the German Federal Water Act : 0...100 °C)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP
Number of digital outputs2
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-40...85
Note on ambient temperature
Medium temperature 100...150 °C
-40...60 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]217
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT04A

9,189,133 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]253
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]362
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT03A

8,857,139 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]153
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Factory settingoils; oil-based media; powder
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]329
Materialsstainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMT01A

6,550,963 ₫

Application
MediaLiquids; viscous media; powder
Medium temperature [°C]-20...85
Probe length [mm]11
Tank pressure [bar]-1...40
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Factory settingoils; oil-based media; powder
Operating conditions
Ambient temperature [°C]-20...60
Storage temperature [°C]-40...85
ProtectionIP 67; (use outside the hazardous area: IP 68 / IP 69)
Mechanical data
Weight [g]218
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK
Process connectionG 1/2 external thread
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMC510

3,912,792 ₫

Application
Mediawater; hydrous media; oils; oil-based media; coolants; powder
Medium temperature [°C]-25...100
Probe length [mm]25
Tank pressure [bar]-1...40
MAWP (for applications according to CRN) [bar]40
Oil
Medium temperature [°C]-25...100
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 35
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]50; (100 (...60 °C))
Short-circuit protectionyes
Type of short-circuit protectionthermal, pulsed
Overload protectionyes
Measuring/setting range
Factory settingoils; oil-based media
Response times
Response time [s]< 0.5
Operating conditions
Ambient temperature [°C]-25...85
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
Mechanical data
Weight [g]115
Dimensions [mm]Ø 18.11 / L = 76.2
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connection1/2" NPT
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMC500

3,912,792 ₫

Application
Mediawater; hydrous media; oils; oil-based media; coolants; powder
Medium temperature [°C]-25...100
Probe length [mm]25
Tank pressure [bar]-1...40
MAWP (for applications according to CRN) [bar]40
Oil
Medium temperature [°C]-25...100
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 35
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]50; (100 (...60 °C))
Short-circuit protectionyes
Type of short-circuit protectionthermal, pulsed
Overload protectionyes
Measuring/setting range
Factory settingwater; hydrous media
Response times
Response time [s]< 0.5
Operating conditions
Ambient temperature [°C]-25...85
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
Mechanical data
Weight [g]116
Dimensions [mm]Ø 18.11 / L = 76.2
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connection1/2" NPT
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMC502

6,343,466 ₫

Application
MediaLiquids; viscous media; powder
Recommended mediawater; hydrous media; oils; oil-based media; powder
Cannot be used forSee the operating instructions, chapter "Function and features".
Probe length [mm]40
Tank pressure [bar]-1...40
MAWP (for applications according to CRN) [bar]40
Oil
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Water
Medium temperature [°C]-20...100
Medium temperature short time [°C]-20...150; (1 h)
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Operating conditions
Ambient temperature [°C]-20...85
Note on ambient temperature
Medium temperature: < 100 °C
-20...60 °C
Medium temperature: < 150 °C
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K
Mechanical data
Weight [g]252
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK; FKM
Process connection1/2" NPT
Surface characteristics Ra/Rz of the wetted parts< 0.8
Displays / operating elements
Display
switching status2 LED, yellow
operating status2 LED, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMC400

3,912,792 ₫

Application
Mediawater; hydrous media; oils; oil-based media; coolants; powder
Cannot be used forSee the operating instructions, chapter "Function and features".
Medium temperature [°C]-25...100
Probe length [mm]9.6
Tank pressure [bar]-1...40
MAWP (for applications according to CRN) [bar]40
Oil
Medium temperature [°C]-25...100
Electrical data
Operating voltage [V]18...30 DC
Current consumption [mA]< 35
Protection classIII
Reverse polarity protectionyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]50; (100 (...60 °C))
Short-circuit protectionyes
Type of short-circuit protectionthermal, pulsed
Overload protectionyes
Measuring/setting range
Factory settingwater; hydrous media
Response times
Response time [s]< 0.5
Operating conditions
Ambient temperature [°C]-25...85
Note on ambient temperature
for installation in probe observe the temperature in the pipe, see installation instructions
Storage temperature [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)
Mechanical data
Weight [g]127.5
Dimensions [mm]Ø 18.1 / L = 76.2
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L); PEEK; FKM
Process connectionG 1/2 external thread
Displays / operating elements
Display
switching statusLEDs, yellow
operating statusLEDs, green
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

IG7107

777,317 ₫

Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designNPN
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]300
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]8
Real sensing range Sr [mm]8 ± 10 %
Operating distance [mm]0...6.48
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]114.8
Mountingnon-flush mountable
Dimensions [mm]M18 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²

 

Mua hàng

IG7104

777,317 ₫

Electrical data
Operating voltage [V]15...30 DC
Current consumption [mA]< 15
Protection classIII
Reverse polarity protectionyes
Outputs
Electrical designPNP
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]400
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Detection zone
Sensing range [mm]5
Real sensing range Sr [mm]5 ± 10 %
Operating distance [mm]0...4.05
Operating conditions
Ambient temperature [°C]-25...70
ProtectionIP 67
Mechanical data
Weight [g]117
Mountingflush mountable
Dimensions [mm]M18 x 1 / L = 61
Materialshousing: brass nickel-plated; sensing face: PBT; lock nuts: brass
Displays / operating elements
Display
switching status1 x LED, yellow
Electrical connection
ConnectionCable: 2 m, PVC, Ø 4.9 mm; 3 x 0.34 mm²

 

Mua hàng