Thiết bị đo

KI5085

3,125,182 ₫

Electrical design          

PNP

Output function          

Normally open / normally closed; (selectable)

Sensing range [mm]

8

Communication interface

IO-Link

Dimensions [mm]       

M30 x 1.5 / L = 90

Operating voltage [V] 

10...30 DC; (10...36 DC (60 °C))

Current consumption [mA]

< 18

Protection class           

III

Reverse polarity protection     

Yes

Output function          

Normally open / normally closed; (selectable)

Max. voltage drop switching output DC [V]   

2.5

Permanent current rating of switching output DC [mA]

100

Switching frequency DC [Hz] 

10

Short-circuit proof      

Yes

Overload protection    

Yes

Detection        

Zone

Sensing range [mm]

8

Ambient temperature [°C]

-25...80

Protection

IP 65; IP 67

Weight [g]       

128.8

Mounting                                                        

Flush mountable

Dimensions [mm]                                           

M30 x 1.5 / L = 90

Thread designation

M30 x 1.5

Materials         

Housing: stainless steel (1.4404 / 316L); pushbuttons: TPE-U; cover: PBT; plug: PEI

Display

Switching status                                   1 x LED, yellow

Electronic lock            

Yes

Accessories (supplied)

Lock nuts: 2

Connection

Connector: 1 x M12

Mua hàng

LT3023

12,836,063 ₫

Number of inputs and outputs

Number of digital outputs: 1; Number of analogue outputs: 1

Output signal  

Switching signal; analogue signal; IO-Link

Electrical design

PNP/NPN

Number of digital outputs

1

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]

200

Number of analogue outputs              

1

Analogue current output [mA]                        

4...20, invertible

Max. load [Ω] 

500

Analogue voltage output [V]                           

...10, invertible

Min. load resistance [Ω]                                              

2000

Short-circuit protection                                               

Yes

Type of short-circuit protection

Thermal, pulsed

Overload protection                                        

Yes

Probe length L [mm]                           

472

Active range A [mm]

390

Application                                         

Mineral oils

Media                         

Hydrous coolants; oils; oil-based media; water; media similar to water

Dielectric constant of the medium                  

> 2

Cannot be used for     

Extremely conductive media; adhering media; granulates; bulk material; acids; alkali

Tank pressure [bar]

0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)

Coolants

Medium temperature [°C]

0...35; (with climatic tube E43101)

Oil

Medium temperature [°C]                   

0...70

Medium temperature short time [°C]           

0...90; (< 1 h)

Water  

Medium temperature [°C]       

0...35; (with climatic tube E43101 35...60 °C)

Operating voltage [V] 

18...30 DC

Current consumption [mA]

< 50

Protection class           

III

Reverse polarity protection                             

Yes

Power-on delay time [s]                      

< 3

Parameter setting options

Hysteresis / window; normally open / normally closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay

Ambient temperature [°C]

0...60

Storage temperature [°C]

-25...80

Protection       

IP 67

Weight [g]

440

Dimensions [mm]       

Ø 16

Materials         

Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV

Materials (wetted parts)           

PP

Display

Display unit                                        

4 x LED, green (cm, inch, °C, °F)

Switching status

1 x LED, yellow

Measured values                                 

Alphanumeric display, 4-digit

Parameter setting                                 

Alphanumeric display, 4-digit

Connection

Connector: 1 x M12

Mua hàng

PI2898

16,952,468 ₫

Output signal  

Switching signal; analogue signal; IO-Link; (configurable)

Measuring range

-0.0124...0.25 bar        -12.4...250 mbar          -5...100.4 inH2O

Process connection

Threaded connection G 1 external thread sealing cone

Application     

Hygienic systems

Media 

Viscous media and liquids with suspended particles; liquids and gases

Medium temperature [°C]

-25...125; (145 max. 1h)

Pressure rating

6000 mbar       2400 inH2O

Min. bursting pressure

30000 mbar     12044 inH2O

Vacuum resistance [mbar]

-1000

Type of pressure                     

Relative pressure

Min. insulation resistance [MΩ]          

100; (500 V DC)

Protection class                                   

III

Reverse polarity protection     

Yes

Integrated watchdog

Yes

2-wire

Operating voltage [V]

20...32 DC

Current consumption [mA]

3.6...21

Power-on delay time [s]          

1

Max. load [Ω] 

300

3-wire

Operating voltage [V]

18...32 DC

Current consumption [mA]

< 45

Power-on delay time [s]

0.5

Max. voltage drop switching output DC [V]

2

Permanent current rating of switching output DC [mA]

250

Switching frequency DC [Hz]

125

Max. load [Ω]                                     

(Ub - 10 V) / 20 mA

Output signal

Switching signal; analogue signal; IO-Link; (configurable)

Electrical design

PNP/NPN

Number of digital outputs

2

Output function          

Normally open / normally closed; (parameterisable)

Number of analogue outputs

1

Analogue current output [mA]

4...20, invertible; (scalable)

Short-circuit protection           

Yes

Type of short-circuit protection

Pulsed

Overload protection

Yes

Measuring range

-0.0124...0.25 bar      -12.4...250 mbar     -5...100.4 inH2O

Damping for the switching output dAP [s]

0...30

Damping for the analogue output dAA [s]

0.01...99.99

Ambient temperature [°C]

-25...80

Storage temperature [°C]

-40...100

Protection       

IP 67; IP 68; IP 69K

Weight [g]

1329.5

Materials         

Stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA

Materials (wetted parts)           

Ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4

Process connection     

Threaded connection G 1 external thread sealing cone

Display

Display unit

LED, green

Switching status                                  

LED, yellow

Function display                                 

Alphanumeric display, 4-digit

Measured values                                 

Alphanumeric display, 4-digit

Display unit    

mbar; kPa; inH2O; mmWS; % of the span

Connection

Connector: 1 x M12; Contacts: gold-plated

Attention: The unit must only be installed in a process connection for G1 sealing cone.

The G1A sealing cone of the unit is only suited for adapters with metal end stop.

Mua hàng

LMT121

5,386,017 ₫

Number of inputs and outputs

Number of digital outputs: 2

Factory setting

Media with low water content

Process connection     

G 1/2 external thread

Application     

Media with low water content

Media                                                                         

Liquids; viscous media; powder

Probe length [mm]

11

Tank pressure [bar]

-1...40; (MAWP (for applications according to CRN): 40 bar / 4 MPa)

Oil, Water

Medium temperature [°C]

-40...100

Medium temperature short time [°C]   

-40...150; (1 h)

Operating voltage [V] 

18...30 DC

Current consumption [mA]

< 50

Protection class           

III

Reverse polarity protection

Yes

Output signal

Switching signal; IO-Link

Electrical design

PNP/NPN

Number of digital outputs                                                                   

2

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]   

100

Short-circuit protection           

Yes

Type of short-circuit protection                                  

Pulsed

Overload protection

Yes

Ambient temperature [°C]

-40...85

Storage temperature [°C]

-40...85

Protection

IP 68; IP 69K

Display

Switching status

LEDs, yellow

Operating status                                  

LEDs, green

Connection     

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LT8022

12,243,924 ₫

Notes   For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet)

 

Number of inputs and outputs

Number of digital outputs: 4

Factory setting

2 switching outputs level (OUT1, OUT2); 2 switching outputs temperature (OUT3, OUT4); mineral oils

Probe length L [mm]

264

Active range A [mm]  

195

Inactive range I1 / I2 [mm]

53 / 16

Media                                                                                                 

Hydrous coolants; oils; oil-based media; water; media similar to water

Dielectric constant of the medium

> 2

Cannot be used for

Extremely conductive media; adhering media; granulates; bulk material; acids; alkali

Tank pressure [bar]     

0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)

Coolants

Medium temperature [°C]

0...35; (with climatic tube E43100)

Oil

Medium temperature [°C]

0...70

Medium temperature short time [°C]

0...90; (< 1 h)

Water

Medium temperature [°C]       

0...35; (with climatic tube E43100 35...65 °C)

Operating voltage [V] 

18...30 DC

Current consumption [mA]

< 50

Protection class           

III

Reverse polarity protection

Yes

Power-on delay time [s]          

< 3

Output signal  

Switching signal; IO-Link

Electrical design          

PNP/NPN

Number of digital outputs

4

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]

200

Short-circuit protection           

Yes

Type of short-circuit protection          

Thermal, pulsed

Overload protection

Yes

Parameter setting options        

Hysteresis / window; normally open / normally closed; SP/rP position; OP position; adjustment OP; medium selection; offset setting; Display unit; process value assignment

Ambient temperature [°C]

0...60

Storage temperature [°C]         

-25...80

Protection

IP 67

Weight [g]

362.5

Dimensions [mm]

Ø 16

Materials                                                                                             

Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PP; PA; TPV

Materials (wetted parts)           

PP

Display           

Display unit

4 x LED, green (cm, inch, °C, °F)

Switching status          

 

4 x LED, yellow (OUT4...OUT1)

Measured values

Alphanumeric display, 4-digit

Parameter setting

Alphanumeric display, 4-digit

Connection                 

Connector: 1 x M12

Mua hàng

PI2789

16,952,468 ₫

Output signal  

Switching signal; analogue signal; IO-Link; (configurable)

Electrical design

PNP/NPN

Number of digital outputs

2

Output function                      

Normally open / normally closed; (parameterisable)

Number of analogue outputs  

1

Analogue current output [mA]

4...20, invertible; (scalable)

Short-circuit protection           

Yes

Type of short-circuit protection          

Pulsed

Overload protection    

Yes

Process connection     

Threaded connection G 1 external thread Aseptoflex Vario

Media             

Hygienic systems ;viscous media and liquids with suspended particles; liquids and gases

Medium temperature [°C]

-25...125; (145 max. 1h)

Pressure rating

4000 mbar       1606 inH2O

Min. bursting pressure

30000 mbar     12044 inH2O

Vacuum resistance [mbar]

-1000

Type of pressure

Relative pressure

No dead space

Yes

 

Min. insulation resistance [MΩ]          

100; (500 V DC)

Protection class                                   

III

Reverse polarity protection

Yes

Integrated watchdog

Yes

2-wire

 

Operating voltage [V]                         

20...32 DC

Current consumption [mA]                             

3.6...21

Power-on delay time [s]                                  

1

Max. load [Ω] 

300

Step response time analogue output [ms]

45

3-wire

Operating voltage [V] 

18...32 DC

Current consumption [mA]                             

< 45

Power-on delay time [s]          

0.5

Max. voltage drop switching output DC [V]

2

Permanent current rating of switching output DC [mA]

250

Switching frequency DC [Hz] 

125

Max. load [Ω] 

(Ub - 10 V) / 20 mA

Min. response time of switching output (dAP) [ms]

3

Step response time analogue output [ms]        

7

Measuring range

-0.005...0.1 bar       -5...100 mbar        -2...40.16 inH2O

Damping for the switching output dAP [s]

0...30

Damping for the analogue output dAA [s]

0.01...99.99

Ambient temperature [°C]

-25...80

Storage temperature [°C]

-40...100

Protection

IP 67; IP 68; IP 69K

Weight [g]

357.5

Materials

Stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA

Materials (wetted parts)

Ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4

Display

Display unit    

LED, green

Switching status

LED, yellow

Function display

Alphanumeric display, 4-digit

Measured values

Alphanumeric display, 4-digit

Display unit                                        

mbar; kPa; inH2O; mmWS; % of the span

Connection

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LT3022

12,119,765 ₫

Media 

Mineral oils ; hydrous coolants; oils; oil-based media; water; media similar to water

Probe length L [mm]

264

Dielectric constant of the medium

> 2

Cannot be used for     

Extremely conductive media; adhering media; granulates; bulk material; acids; alkali

Tank pressure [bar]

0.5; (when mounting with mounting accessories: E43001 - E43007, E43019)

Coolants

Medium temperature [°C]

0...35; (with climatic tube E43100)

Oil

Medium temperature [°C]       

0...70

Medium temperature short time [°C]

0...90; (< 1 h)

Water  

Medium temperature [°C]

0...35; (with climatic tube E43100 35...65 °C)

Operating voltage [V] 

18...30 DC

Current consumption [mA]     

< 50

Protection class           

III

Reverse polarity protection

Yes

Power-on delay time [s]          

< 3

Output signal  

Switching signal; analogue signal; IO-Link

Electrical design

PNP/NPN

Number of digital outputs

1

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]   

2.5

Permanent current rating of switching output DC [mA]

200

Number of analogue outputs  

1

Analogue current output [mA]

4...20, invertible

Max. load [Ω]

500

Analogue voltage output [V]   

...10, invertible

Min. load resistance [Ω]          

2000

Short-circuit protection                       

Yes

Type of short-circuit protection          

Thermal, pulsed

Overload protection    

Yes

Probe length L [mm]   

264

Parameter setting options

Hysteresis / window; normally open / normally closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay.

Ambient temperature [°C]

0...60

Storage temperature [°C]

-25...80

Protection       

IP 67

Weight [g]

353

Dimensions [mm]       

Ø 16

Materials         

Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV

Materials (wetted parts)                                                           

PP

Display           

Display unit

4 x LED, green (cm, inch, °C, °F)

Switching status

1 x LED, yellow

Measured values

Alphanumeric display, 4-digit

Parameter setting         

Alphanumeric display, 4-digit

Connection

Connector: 1 x M12

 

Mua hàng

LMT105

6,693,246 ₫

Number of inputs and outputs

Number of digital outputs: 2

Process connection

G 1/2 external thread

Media

Liquids; viscous media; powder

Recommended media 

Water; hydrous media; oils; oil-based media; powder

Probe length [mm]                  

253

Tank pressure [bar]

-1...40

Oil, Water

Medium temperature [°C]

-20...100

Medium temperature short time [°C]

-20...150; (1 h)

Operating voltage [V]

18...30 DC

Current consumption [mA]

< 50

Protection class           

III

Reverse polarity protection

Yes

Output signal  

Switching signal; IO-Link

Electrical design

PNP/NPN

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]

100

Short-circuit protection           

Yes

Type of short-circuit protection          

Pulsed

Overload protection    

Yes

Ambient temperature [°C]       

-20...85

Storage temperature [°C]

-40...85

Protection

IP 68; IP 69K

Display

Switching status

LEDs, yellow

Operating status          

LEDs, green

Connection     

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LR9020

9,225,920 ₫

Number of inputs and outputs

Number of digital outputs: 1; Number of analogue outputs: 1

Process connection

G 3/4 external thread

Media 

Hydrous coolants; oils; oil-based media; water; media similar to water

Dielectric constant of the medium

≥ 2; (for media with a dielectric constant of 2...20 (e.g. oils), a coaxial pipe is needed for operation)

Medium temperature [°C]

0...80; (90 < 1 h)

Tank pressure [bar]

-1...16

Operating voltage [V] 

18...30 DC

Current consumption [mA]     

< 80

Protection class           

III

Reverse polarity protection

Yes

Power-on delay time [s]          

< 3

Output signal                          

Analogue signal; IO-Link

Number of digital outputs

1

Number of analogue outputs  

1

Analogue current output [mA]

4...20

Max. load [Ω]                                     

500

Analogue voltage output [V]   

0...10

Min. load resistance [Ω]                      

2000

Overload protection    

Yes

Probe length L [mm]   

100...1600

Ambient temperature [°C]

0...60

Storage temperature [°C]

-25...80

Protection

IP 68; IP 69K

Weight [g]

430

Materials

Stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI

Materials (wetted parts)           

Stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre

Connection     

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LR8000

11,231,556 ₫

Notes:              For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).Number of inputs and outputs

Number of digital outputs

4

Probe length L [mm]   

100...1600

Process connection

G 3/4 external thread

Media 

Hydrous coolants; oils; oil-based media; water; media similar to water

Dielectric constant of the medium

≥ 2; (for media with a dielectric constant of 2...20 (e.g. oils), a coaxial pipe is needed for operation)

Cannot be used for

Greases; granulates; bulk material; acids; alkali; heavily foaming media

Medium temperature [°C]

0...80; (90 < 1 h)

Tank pressure [bar]

-1...16

Operating voltage [V]

18...30 DC

Current consumption [mA]

< 80

Protection class           

III

Reverse polarity protection

Yes

Power-on delay time [s]          

< 3

Output signal  

Switching signal; IO-Link

Electrical design

PNP

Output function          

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]

2.5

Permanent current rating of switching output DC [mA]

200

Short-circuit protection           

Yes

Type of short-circuit protection          

Thermal, pulsed

Probe length L [mm]   

100...1600

Active range A [mm]  

L-40 (L-60); (when set to oil and oil based media)

Ambient temperature [°C]

0...60

Storage temperature [°C]

-25...80

Protection       

IP 67

Weight [g]

396.5

Materials         

Stainless steel (1.4301 / 304); FKM; PBT; PC; PEI; TPE-V; PTFE

Materials (wetted parts)

Stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20

Display

Display unit    

3 x LED, green

Switching status

4 x LED, yellow

Level

Alphanumeric display, 4-digit

Parameter setting

Alphanumeric display, 4-digit

Accessories (optional)

Probe:, E43203...E43205 / E43207...E43210

Coaxial pipe:, E43211...E43221, E43223, E43224

Connection                 

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LMC410

3,912,792 ₫

Number of inputs and outputs            

Number of digital outputs: 2

Media             

Oils; oil-based media water; hydrous media; oils; oil-based media; coolants; powder

Process connection     

G 1/2 external thread

Output signal                          

Switching signal; IO-Link

Electrical design          

PNP/NPN

Output function                      

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]   

2.5

Permanent current rating of switching output DC [mA]

50; (100 (...60 °C))

Short-circuit protection           

Yes

Type of short-circuit protection                      

Thermal, pulsed

Overload protection                            

Yes

Medium temperature [°C]       

-25...100

Probe length [mm]                  

9.6

Tank pressure [bar]     

-1...40

Medium temperature (Oil) [°C]

-25...100

Current consumption [mA]     

< 35

Protection class           

III

Reverse polarity protection     

Yes

Response time [s]                   

< 0.5

Ambient temperature [°C]

-25...85

Storage temperature [°C]

-40...85

Protection

IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)

Weight [g]

127.5

Dimensions [mm]

Ø 18.1 / L = 76.2

Materials

Stainless steel (1.4404 / 316L); PEEK; PEI; FKM

Materials (wetted parts)           

Stainless steel (1.4404 / 316L); PEEK; FKM

Display

Switching status

LEDs, yellow

Operating status

LEDs, green

Connection

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng

LR2750

22,042,883 ₫

Number of inputs and outputs            

Number of digital outputs: 1; Number of analogue outputs: 1

Media             

Liquids

Output signal  

Switching signal; analogue signal; IO-Link

Electrical design

PNP/NPN

Number of digital outputs       

1

Output function                                  

Normally open / normally closed; (parameterisable)

Max. voltage drop switching output DC [V]   

2.5

Permanent current rating of switching output DC [mA]

150; (200 (...60 °C))

Number of analogue outputs  

1

Analogue current output [mA]

4...20, invertible; (scalable)

Short-circuit protection           

Yes

Type of short-circuit protection                      

Pulsed

Overload protection                

Yes

Probe length L [mm]               

150...2000

Recommended media             

Water; hydrous media

Medium temperature [°C]

-40...150; (For 3-A applications, the medium temperature is limited to 121 °C and COP cleaning is required.)

Tank pressure [bar]

-1...40

Operating voltage [V]             

18...30 DC

Current consumption [mA]                 

< 50

Protection class                       

III

Reverse polarity protection     

Yes

Power-on delay time [s]                                              

< 3

Ambient temperature [°C]                               

-40...80

Storage temperature [°C]                     

-40...100

Protection                                           

IP 68; IP 69K

Weight [g]                   

401.5

Materials                                                         

Stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM

Materials (wetted parts)                                   

Stainless steel (1.4404 / 316L); PEEK; EPDM

Process connection                             

G 1 Aseptoflex Vario

Display

Display unit                            

3 x LED, green

Switching status                      

2 x LED, yellow

Level                          

Alphanumeric display, 4-digit

Parameter setting                     

Alphanumeric display, 4-digit

Connection                                                     

Connector: 1 x M12; Contacts: gold-plated

 

Mua hàng