PM1706

11,791,733 ₫

Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
20000 mbar290 psi2000 kPa
Min. bursting pressure
50000 mbar725 psi5000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]20
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-0.125...2.5 bar-125...2500 mbar-1.82...36.26 psi-12.5...250 kPa
Analogue start point
-125...2000 mbar-1.82...29 psi-12.5...200 kPa
Analogue end point
375...2500 mbar5.44...36.26 psi-37.5...250 kPa
In steps of
1 mbar0.02 psi0.1 kPa
Factory setting
ASP = 0.0 mbarAEP = 2500 mbar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitmbar; psi; kPa; mWS; inH2O
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1705

11,791,733 ₫

Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
30 bar435 psi3000 kPa
Min. bursting pressure
100 bar1450 psi10000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]30
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-1...4 bar-14.5...58 psi-100...400 kPa
Analogue start point
-1...3.2 bar-14.5...46.4 psi-100...320 kPa
Analogue end point
-0.2...4 bar-2.9...58 psi-20...400 kPa
In steps of
0.02 bar0.05 psi0.2 kPa
Factory setting
 ASP = 0.0 barAEP = 4.0 bar
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]282.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitbar; psi; kPa
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1715

11,791,733 ₫

Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
30 bar435 psi3000 kPa
Min. bursting pressure
100 bar1450 psi10000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]30
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-1...6 bar-14.5...87 psi-100...600 kPa
Analogue start point
-1...4.8 bar-14.5...69.6 psi-100...480 kPa
Analogue end point
0.2...6 bar2.9...87 psi20...600 kPa
In steps of
0.02 bar0.05 psi0.2 kPa
Factory setting
 ASP = 0.0 barAEP = 6.0 bar
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitbar; psi; kPa
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

PM1703

11,791,733 ₫

Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
100 bar1450 psi10 MPa
Min. bursting pressure
350 bar5075 psi35 MPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]60
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-1...25 bar-14.6...362.6 psi-0.1...2.5 MPa
Analogue start point
-1...20 bar-14.6...290 psi-0.1...2 MPa
Analogue end point
4...25 bar58...362.6 psi0.4...2.5 MPa
In steps of
0.01 bar0.2 psi0.001 MPa
Factory setting
ASP = 0.0 barAEP = 25.0 bar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles100 million
Tightening torque [Nm]35; (recommended tightening torque depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitbar; psi; MPa
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1709

12,144,477 ₫

Product characteristics
Output signalanalogue signal
Measuring range
-1...1 bar-1000...1000 mbar-14.5...14.5 psi-100...100 kPa
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
10000 mbar145 psi1000 kPa
Min. bursting pressure
30000 mbar435 psi3000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]10
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-1...1 bar-1000...1000 mbar-14.5...14.5 psi-100...100 kPa
Analogue start point
-1000...600 mbar-14.5...8.7 psi-100...60 kPa
Analogue end point
-600...1000 mbar-8.7...14.5 psi-60...100 kPa
In steps of
1 mbar0.01 psi0.1 kPa
Factory setting
 ASP = -1000 mbarAEP = 1000 mbar
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles100 million
Tightening torque [Nm]35; (recommended tightening torque depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitmbar; psi; kPa; mWS; inH2O
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1789

12,144,477 ₫

Product characteristics
Output signalanalogue signal
Measuring range
-0.005...0.1 bar-5...100 mbar-0.073...1.45 psi-0.5...10 kPa
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
4000 mbar58 psi400 kPa
Min. bursting pressure
30000 mbar435 psi3000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]4
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-0.005...0.1 bar-5...100 mbar-0.073...1.45 psi-0.5...10 kPa
Analogue start point
-5...80 mbar-0.073...1.16 psi-0.5...8 kPa
Analogue end point
15...100 mbar0.218...1.45 psi1.5...10 kPa
In steps of
0.05 mbar0.001 psi0.005 kPa
Factory setting
ASP = 0.0 mbarAEP = 100 mbar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]279.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles100 million
Tightening torque [Nm]35; (recommended tightening torque depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitmbar; psi; kPa; mmWS; inH2O
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1704

11,791,733 ₫

Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
50 bar725 psi5 MPa
Min. bursting pressure
150 bar2175 psi15 MPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]50
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-1...10 bar-14.5...145 psi-100...1000 kPa-0.1...1 MPa
Analogue start point
-1...8 bar-14.5...116 psi-0.1...0.8 MPa
Analogue end point
1...10 bar14.5...145 psi0.1...1 MPa
In steps of
0.005 bar0.1 psi0.0005 MPa
Factory setting
ASP = 0.0 barAEP = 10.0 bar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitbar; psi; MPa
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng

PM1708

12,144,477 ₫

Product characteristics
Output signalanalogue signal
Measuring range
-0.0125...0.25 bar-12.5...250 mbar-0.182...3.626 psi-1.25...25 kPa
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
6000 mbar84 psi600 kPa
Min. bursting pressure
30000 mbar435 psi3000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]10
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-0.0125...0.25 bar-12.5...250 mbar-0.182...3.626 psi-1.25...25 kPa
Analogue start point
-12.5...200 mbar-0.182...2.9 psi-1.25...20 kPa
Analogue end point
37.5...250 mbar0.544...3.626 psi3.75...25 kPa
In steps of
0.1 mbar0.002 psi0.01 kPa
Factory setting
ASP = 0.0 mbarAEP = 250 mbar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles100 million
Tightening torque [Nm]35; (recommended tightening torque depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitmbar; psi; kPa; mmWS; inH2O
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

PM1707

12,144,477 ₫

Product characteristics
Output signalanalogue signal
Measuring range
-0.05...1 bar-50...1000 mbar-0.73...14.5 psi-5...100 kPa
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Application
Measuring elementceramic-capacitive pressure measuring cell
Applicationhygienic systems
Mediaviscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]-25...125; (150 max. 1h)
Pressure rating
10000 mbar145 psi1000 kPa
Min. bursting pressure
30000 mbar435 psi3000 kPa
Vacuum resistance [mbar]-1000
Type of pressurerelative pressure
No dead spaceyes
MAWP (for applications according to CRN) [bar]10
Electrical data
Operating voltage [V]18...30 DC
Min. insulation resistance [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Integrated watchdogyes
2-wire
Current consumption [mA]3.5...21.5
Power-on delay time [s]1
3-wire
Current consumption [mA]< 45
Power-on delay time [s]0.5
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proofyes
Overload protectionyes
Measuring/setting range
Measuring range
-0.05...1 bar-50...1000 mbar-0.73...14.5 psi-5...100 kPa
Analogue start point
-50...800 mbar-0.73...11.6 psi-5...80 kPa
Analogue end point
150...1000 mbar2.18...14.5 psi15...100 kPa
In steps of
0.5 mbar0.01 psi0.05 kPa
Factory setting
ASP = 0.0 mbarAEP = 1000 mbar 
Response times
Damping for the analogue output dAA [s]0...4
2-wire
Step response time analogue output [ms]30
3-wire
Step response time analogue output [ms]7
Operating conditions
Ambient temperature [°C]-25...80
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]281.5
Materialsstainless steel (1.4404 / 316L); PBT
Materials (wetted parts)ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4
Min. pressure cycles100 million
Tightening torque [Nm]35; (recommended tightening torque depends on lubrication, seal and pressure rating)
Process connectionthreaded connection G 1 external thread Aseptoflex Vario
Displays / operating elements
Display unitmbar; psi; kPa; mWS; inH2O
Electrical connection
ConnectionConnector: 1 x M12; Contacts: gold-plated

 

Mua hàng
HOT

TA2812

5,146,204 ₫

Product characteristics
Number of inputs and outputsNumber of analogue outputs: 1
Measuring range [°C]-50...200
Process connectionClamp 1,5" ISO 2852
Installation length EL [mm]50
Application
Measuring element1 x Pt 1000; (to DIN EN 60751, class A)
Medialiquids and gases
Pressure rating [bar]100
Vacuum resistance [mbar]-1000
MAWP (for applications according to CRN) [bar]55
Electrical data
Operating voltage [V]18...32 DC; ("supply class 2" to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link; (configurable)
Number of analogue outputs1
Analogue current output [mA]4...20
Max. load [Ω]250; ((18...19 V); 19...32 V: 300 Ω)
Short-circuit protectionyes
Overload protectionyes
Measuring/setting range
Measuring range [°C]-50...200
Factory setting0...200 °C
Resolution
Resolution of analogue output [K]0.04
Response times
Dynamic response T05 / T09 [s]< 0,5 / < 2
Operating conditions
Ambient temperature [°C]-25...80
Note on ambient temperature
at medium temperature: < 160 °C
-25...60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40...100
ProtectionIP 67; IP 68; IP 69K
Mechanical data
Weight [g]231.5
Dimensions [mm]Ø 18.71
Materialsstainless steel (1.4404 / 316L); PEI; FKM
Materials (wetted parts)stainless steel (1.4404 / 316L) electropolished
Process connectionClamp 1,5" ISO 2852
Surface characteristics Ra/Rz of the wetted partsRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]50
Electrical connection
ConnectionConnector: 1 x M12
Mua hàng

PS3208

11,521,987 ₫

Output signal  

Analogue signal          

Number of analogue outputs  

1

Analogue current output [mA]

4...20

Max. load [Ω] 

700; (Ub = 24 V; (Ub - 10 V) / 20 mA)

Short-circuit protection

Yes

Measuring range

0...0.25 bar      0...250 mbar

Design

With capillary tube for pressure compensation

Media 

Liquids

Medium temperature [°C]       

-10...50

Pressure rating [bar]

2

Min. bursting pressure [bar]    

2.4

Type of pressure

Relative pressure

Operating voltage [V] 

10...30 DC

Protection class                       

III

Reverse polarity protection

Yes

Ambient temperature [°C]       

-10...50

Storage temperature [°C]

-30...80

Protection       

IP 68

Weight [g]       

548

Materials         

Stainless steel (1.4571/316Ti ); PA

Connection     

Cable: 5 m, PUR, Ø 7.5 mm; Core insulation:, PVC

 

Mua hàng

KI5085

3,125,182 ₫

Electrical design          

PNP

Output function          

Normally open / normally closed; (selectable)

Sensing range [mm]

8

Communication interface

IO-Link

Dimensions [mm]       

M30 x 1.5 / L = 90

Operating voltage [V] 

10...30 DC; (10...36 DC (60 °C))

Current consumption [mA]

< 18

Protection class           

III

Reverse polarity protection     

Yes

Output function          

Normally open / normally closed; (selectable)

Max. voltage drop switching output DC [V]   

2.5

Permanent current rating of switching output DC [mA]

100

Switching frequency DC [Hz] 

10

Short-circuit proof      

Yes

Overload protection    

Yes

Detection        

Zone

Sensing range [mm]

8

Ambient temperature [°C]

-25...80

Protection

IP 65; IP 67

Weight [g]       

128.8

Mounting                                                        

Flush mountable

Dimensions [mm]                                           

M30 x 1.5 / L = 90

Thread designation

M30 x 1.5

Materials         

Housing: stainless steel (1.4404 / 316L); pushbuttons: TPE-U; cover: PBT; plug: PEI

Display

Switching status                                   1 x LED, yellow

Electronic lock            

Yes

Accessories (supplied)

Lock nuts: 2

Connection

Connector: 1 x M12

Mua hàng