| Product characteristics | 
|---|
| Output signal | analogue signal | 
| Measuring range | | -0.0125...0.25 bar | -12.5...250 mbar | -0.182...3.626 psi | -1.25...25 kPa | 
 | 
| Process connection | threaded connection G 1 external thread Aseptoflex Vario | 
| Application | 
|---|
| Measuring element | ceramic-capacitive pressure measuring cell | 
| Application | hygienic systems | 
| Media | viscous media and liquids with suspended particles; liquids and gases | 
| Medium temperature [°C] | -25...125; (150 max. 1h) | 
| Pressure rating |  | 
| Min. bursting pressure | | 30000 mbar | 435 psi | 3000 kPa | 
 | 
| Vacuum resistance [mbar] | -1000 | 
| Type of pressure | relative pressure | 
| No dead space | yes | 
| MAWP (for applications according to CRN) [bar] | 10 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18...30 DC | 
| Min. insulation resistance [MΩ] | 100; (500 V DC) | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Integrated watchdog | yes | 
| 2-wire | 
|---|
| Current consumption [mA] | 3.5...21.5 | 
| Power-on delay time [s] | 1 | 
| 3-wire | 
|---|
| Current consumption [mA] | < 45 | 
| Power-on delay time [s] | 0.5 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of analogue outputs: 1 | 
| Outputs | 
|---|
| Total number of outputs | 1 | 
| Output signal | analogue signal | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4...20; (scalable) | 
| Max. load [Ω] | 700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) | 
| Short-circuit proof | yes | 
| Overload protection | yes | 
| Measuring/setting range | 
|---|
| Measuring range | | -0.0125...0.25 bar | -12.5...250 mbar | -0.182...3.626 psi | -1.25...25 kPa | 
 | 
| Analogue start point | | -12.5...200 mbar | -0.182...2.9 psi | -1.25...20 kPa | 
 | 
| Analogue end point | | 37.5...250 mbar | 0.544...3.626 psi | 3.75...25 kPa | 
 | 
| In steps of | | 0.1 mbar | 0.002 psi | 0.01 kPa | 
 | 
| Factory setting | | ASP = 0.0 mbar | AEP = 250 mbar |  | 
 | 
| Response times | 
|---|
| Damping for the analogue output dAA [s] | 0...4 | 
| 2-wire | 
|---|
| Step response time analogue output [ms] | 30 | 
| 3-wire | 
|---|
| Step response time analogue output [ms] | 7 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -25...80 | 
| Storage temperature [°C] | -40...100 | 
| Protection | IP 67; IP 68; IP 69K | 
| Mechanical data | 
|---|
| Weight [g] | 281.5 | 
| Materials | stainless steel (1.4404 / 316L); PBT | 
| Materials (wetted parts) | ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4 | 
| Min. pressure cycles | 100 million | 
| Tightening torque [Nm] | 35; (recommended tightening torque depends on lubrication, seal and pressure rating) | 
| Process connection | threaded connection G 1 external thread Aseptoflex Vario | 
| Displays / operating elements | 
|---|
| Display unit | mbar; psi; kPa; mmWS; inH2O | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |